4 AUXILIARY AND APPLIED FUNCTIONS

4.5.4 Password save

Operation
Read
Write
Verification
ROM writing
Online change
Backup
Load
Register/change
password
Delete password
Project diversion
Registered/changed/deleted password or password read with user data from "Read
from CPU" screen displayed by menu [Online]
project data.
A password saved in a project data can be registered with user data, when the user
data are written in the Motion CPU that does not set password from "Write to CPU"
screen displayed by menu [Online]
Select menu [Project]
(1) Status of password data for each operation
When a password is set in the call source Motion CPU, the password contents
are called and the password data in a project are updated.
When a password data is set in a project, if a password is not set in the write
designation Motion CPU, the password contents are also written.
Password data in a project are not updated.
Password contents registered in the write designation Motion CPU are written in
ROM.
Password contents of write designation Motion CPU are not updated.
It is saved in backup data including also the password contents registered in the
call source Motion CPU. The password data in a project is not updated.
Password contents in backup data are written in the write designation Motion
CPU.
New password contents are written in the write designation Motion CPU.
Password data in a project is also updated to new password contents.
A password is deleted from the write designation Motion CPU.
A password is deleted also from the password data in a project.
The password data in diverting source project is not diverted.
POINT
(1) The password data is not save in a project without project save.
(2) Save a project after delete of password to delete the password data in a
project. Or, create a project without password data by creating new project
and diverting user data from a project with password data.
[Write to CPU].
[Save] to save the updated password data in a project.
Status of password data
4 - 25
[Read from CPU] can be saved in a

Advertisement

Table of Contents

   Also See for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

   Related Manuals for Mitsubishi Electric MOTION CONTROLLERS Q172DCPU

This manual is also suitable for:

Q173dcpu

Comments to this Manuals

Symbols: 0
Latest comments:
  • p Dec 14, 2015 07:47:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by ...
  • p Dec 14, 2015 07:32:
    This video describes how to eliminate the 'InS' message on a Mitsubishi Q Series motion controller by