1
Complete Procedure 25: Hardware powerdown.
2
Loosen the screws at the top and bottom of the card.
3
Use the ejectors to unlock the card.
4
Pull the MVME147 card out of the Application Module.
5
Slide the MVME167 card into the Application Module. Firmly press
the middle of the faceplate to seat the card.
6
Tighten the screws on the faceplate of the replacement card.
7
Restore power to the Application Module by setting the MPDU circuit
breaker to ON (up).
The system reboots into the ÒConsole Login:Ó prompt.
8
Complete Procedure 6: Load the operating system tape on an IPE
Module or an Application Module with an MVME167 card.
9
Complete Procedure 7: Reboot and go through setup.
10
Complete Procedure 8: Load the application software from tape.
11
Complete Procedure 9: Restore configuration files and data files
from the backup tape.