430 Chapter 14: Software installation, upgrade, and update procedures
553-3202-210 Standard October 1998
Procedure 6: Load the operating system tape on an IPE Module or an
Application Module with an MVME167 card (continued)
4
At the Ò4120-Diag>Ó or Ò4120-Bug>Ó prompt, type env and press
[Return].
The environment prompts appear. Answer them as indicated in the
following figure. Then go to step 6.
Figure 173
Environment prompts (IPE Module)
Bug or System environment [B/S] = B?
Field Service Menu Enable [Y/N] = N?
Probe System for Supported I/O Controllers [Y/N] = Y?
Local SCSI Bus Reset on Debugger Startup [Y/N] = Y?
Ignore CFGA Block on a Hard Disk Boot [Y/N] = Y?
Auto Boot Enable [Y/N]
Auto Boot at power-up only [Y/N] = N?
Auto Boot Controller LUN = 00?
If you make a mistake, quit the process by entering a period (.) at a
prompt and answering n for the last two questions (Update Non-
Volatile RAM/Reset Local System). This brings you back to the Ò167-
Diag>Ó or Ò4120-Diag>Ó prompt. Then type env;d and press [Return]
to undo the mistakes you made and bring back the original default
values.
Note: At the ÒAuto Boot Controller LUN=00?Ó prompt, type a period
and press [Return] to bypass additional prompts that do not need to be
changed.
<cr>
<cr>
<cr>
= Y?
<cr>
(Type a period and press
. <cr>
[Return].)
<cr>
<cr>
<cr>