538 Chapter 19: Single Terminal Access
553-3202-210 Standard October 1998
8
Configure the MSDL port for STA. Define the port and its
characteristics by responding to the following prompts in LD 17.
Substitute the device number where ÒxÓ appears in the Response
column.
Table 147
LD 17ÑConfigure MSDL port
Prompt
Response
REQ
CHG
TYPE
CFN
ADAN
NEW TTY x
CTYP
MSDL
GRP
0
DNUM
x
PORT
0
DES
STA_ADMIN
BPS
9600
PARY
NONE
STOP
1
BITL
8
PARM
RS-232 DCE
FUNC
ABD FCL LME
USER
MTC SCH BUG
XSM
NO
TTYLOG <cr>
<cr> through remaining prompts
Comment
Create or change information in the database
Configuration record data block
Add TTY with a logical ID x (0-15). The TTY
number must be the same as the DNUM of
the MSDL.
Card type is MSDL (automatic response)
Network Group Number (this prompt appears
only for Option 81 systems)
Device number; same as TTY (automatic
response)
Admin port number (automatic response)
Designate port 0 for the STA terminal.
Baud rate
Parity type
Number of stop bits
Data bit length
Interface and transmission mode
MSDL card functions
Output message types
SDI port for the system monitor
Log buffer size