Chapter 15: Link Configuration; Default Configuration; Link 0Ñapplication Module Link - Meridian Link/Customer Controlled Routing Installation And Upgrade Manual

Meridian controlled routing installation and upgrade guide
Table of Contents

Advertisement

Chapter 15: Link configuration

Default configuration

Link 0ÑApplication Module Link
This chapter describes the initial configuration procedures for the links used
by the applications, and refers to the procedures in Chapter 14, ÒSoftware
installation, upgrade, and update proceduresÓ earlier in this guide.
Note: The redundancy feature does not affect link configurations as
described in this chapter.
Systems shipped from the factory are configured as described in the
following sections. The default configuration for link 0 applies to Meridian
Link, CCR, and co-resident systems. Configurations for link 1 and link 2 are
for Meridian Link and co-resident systems only.
Link 0 is defined as the Application Module Link (AML), with the
following characteristics (which are described in more detail later in this
chapter):
Protocol: HDLC
Machine ID: SL16
Delay: 0
Port type: H
PDN type: 0
Baud rate: 19200
RFS timer: 150
Remote address: 3
Maximum out frames (K): 7
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Link type: 1
Physical DTE(0)/DCE(1): 0
Maximum Frame length: 135
Fail timer: 50
Internal address: 1
T1: 20
Maximum trans attempts: (N2): 8
479