10.7. Configuring system options

In the installer menu, use the control buttons to select the fourth menu
item.
You see the following graphic display:
Select this menu item by pressing the control button
word Select.
You see the following graphic display:
Use the control buttons
and their attributes, see Table 12 on the next page. Confirm your
selection by pressing the control button
Zum Abbrechen der Eingabe drücken Sie die Kontrolltaste
unterhalb der Anzeige Zurück.
to select a function. For a list of functions
under the word Select.
Function
User access
Remote access
Language
Restore defaults
Installer code
Entry timer unset
under the
PA Response
System Auto Rearm
Siren Delay
Siren Time
Entry Timer on Unset
Supervision
Response
Jamming Detection
Batt Load Test
Siren in PSet
Force Set
RF Siren Options
Table 12: System settings
42
Meaning
Here you define the options available to the
user in the user menu.
This menu controls access to the remote
control feature.
Select the language for text output and the
graphic displays. You can choose between two
languages.
For restoring the factory settings and setting the
country parameters (important for telephone
communication)
For entering a new user code
To unset the panel/partition with a wireless
remote control during the entry delay.
If this function is activated you can only unset
the panel with the wireless remote control when
the entry delay is running. If this function is not
activated the panel can be unset with the
wireless remote control at any time.
For setting response to panic alarm
Setting of panel for response following an alarm
For setting the length of the siren delay
For setting the siren duration
For setting the delay time for entry alarm
Fail
For setting the response of the panel in the case
of a monitoring failure
For setting the response of the panel in the case
of radio jamming
To activate the battery test function
To control the sounder functions during part set
of a partition / panel
To activate the function Force Set.
This menu allows you to select how the radio
siren responds during Fire, Burglar or PA
alarms.