3. Precautions
!
WARNING
To avoid fire and injury, please observe the
following:
Securely fasten the device at a dry
•
location in the building.
Ensure sufficient air circulation for the
•
alarm station.
Do not expose the panel to
•
temperatures less than 0°C or more
than 50°C.
The panel is designed for indoor use
•
only.
Humidity must not exceed 90% (non-
•
condensed).
Make sure that no metal objects can
•
be pushed into the equipment from
outside.
Ensure that the voltage is disconnected
•
when carrying out work on the station.
!
!
Please observe the following regulations to
ensure trouble-free operation of your
system.
The alarm panel is supplied with DC
•
power by means of the internal
transformer.
The transformer is connected to the
•
230V AC building mains by means of
a separate, electrically protected
line.
Connection work to the building
•
mains is subject to country-specific
regulations.
A rechargeable battery supplies
•
emergency standby power.
The maximum power consumption of
•
connected components must never
exceed 1A.
Always replace fuses with fuses of the
•
same rating, never higher.
!
IMPORTANT
5
!
IMPORTANT INFO
Burglar alarm stations in general:
If the equipment is not correctly installed,
signals may be misinterpreted and result in
false alarms. The costs resulting from the
deployment of rescue organisations, e.g.: fire
or police, are borne by the operator of the
equipment. Therefore please read the
instructions very carefully and follow the
installation instructions for lines and
components precisely.
!