10.7.12. Supervision Fail Response

Use the control buttons
selection by pressing the control button
cancel input, press the control button
If you confirm Supervision with the Select button, you see the following
graphic display:
Use the control buttons
table below. To select a function, press the control button
the word Select. To cancel input, press the control button
the word Back.
If there is no status message from a detector for more than two hours
the radio alarm panel raises an alarm.:
to select Supervision. Confirm your
under the word Select. To
under the word Back.
to select a function as described in the
Function
Disabled
Fault
Tamper
Alarm
If the alarm system must meet EN50131-3 radio supervision requirements
then enable Supervision. Once enabled, the radio alarm panel will
under
prevent the user from setting the system if a detector has lost contact
with the radio alarm panel for more than 15 minutes.
under
49
Meaning for activated
Meaning for
system
deactivated system
No response
No response
Fault is reported by
Fault is reported on
telephone.
display and by signal
tone.
External alarm
Fault is reported on
Transmission of
display and by signal
supervision failure and
tone.
tamper
External alarm
Transmission of
supervision failure and
tamper
External alarm
Alarm message on
Transmission of
display and signal tone
supervision failure and
alarm