Abus SECVEST 868 Installation Instructions Manual page 71

Table of Contents

Advertisement

10.10.1.14 Static Test Call
In static testing the system makes a test call either at one particular
time of day or on one day every month.
To make test calls at a set time every day select
Reporting, Alarms, Static Test Call, Daily. From the display select a
number between 01 and 24 to choose the time of day for the call.
For example, select 18 to program the radio alarm panel to make a
static test call at 6:00pm every day.
To make test calls on one day every month select
Reporting, Alarms, Static Test Call, Monthly. From the display select a
number between 1 and 31 to specify the day of the month on which
the call should take place. The radio alarm panel will make a test
call at 1am on the selected day.
Note that the radio alarm panel will add or subtract up to 16
minutes at random to the time you specified. This is to make sure
that the ARC is not overwhelmed with a flood of test calls from
systems that have all been given the same time.
Select Reporting, Alarms, Static Test Call, Disabled to disable static test
calls.
10.10.1.15. Burg Comms Rearm
Press the control button
by pressing the control button
input, press the control button
If you confirm Burg Comms Rearm with the Select button, you see the
following graphic display:
Use the control buttons
channel 3 pf the Fast Format report following expiry of the delay time
and then rearm it if there is a new alarm. If this function is enabled, all
zones in alarm state are hidden. If the function is enabled, this channel
is disabled until the panel is deactivated and rearmed. Select a
function by pressing the control button
cancel input, press the control button
71
to select Burg Comms Rearm and confirm
under the word Select. To cancel
under the word Back.
to select whether the panel is to reset
under the word Select. To
under the word Back.