Function
Meaning
Not used
This output is not in use and is never activated.
(Exception: complete power loss)
Siren
This output is activated on local alarms for the
defined siren duration.
E/E Follow
This output is activated for the duration of the
delay time (entry/exit delay active).
Armed Lamp
This output is activated as long as the alarm
panel is completely or internally activated.
24 Hour
This output is activated if a 24-hour zone triggers
an alarm.
Strobe
This output is activated for a local alarm and
remains active until the radio alarm panel is
deactivated.
Strobe Set
This output is activated for approx. 10 seconds
following successful activation of the radio
alarm panel and is used for acknowledging
activation. In addition this function needs to be
activated in the menu partitions. This output is
also activated for a local alarm and remains
active until the radio alarm panel is
deactivated.
Pulse Set
This output is activated for approx. 1 second
following successful activation of the radio
alarm station.
Pulse Unset
This output is activated for approx. 1 second
following successful deactivation of the radio
alarm panel as well as for a panic or fire alarm.
Setting complete
This output is activated for approx. 10 seconds
following successful activation of the radio
alarm station.
Siren P1 – P4
This output is activated on local alarms in the
selected partition for the defined siren duration.
Strobe P1 – P4
This output is activated for a local alarm in the
selected partition and remains active until the
radio alarm panel is deactivated. In addition
this output is activated for ten seconds when
the partition has been successfully activated.
Technical Alarm
This output is activated if a technical zone
triggers an alarm.
Function
Meaning
Medical
This output is activated if a social call is
activated.
PA
This output is activated if a panic alarm is
activated.
Fire
This output is activated if a fire alarm is
activated.
Zone follow
This output follows the state of a zone. If you
select this type, you see a list of zones. Select a
zone.
User defined
This zone can be remote-controlled by various
components such as: remote radio alarm panel
or code keypad. The output can also be
assigned times at which it is to be activated
and deactivated. If you select this output type,
you can enter the times at which the output is
to be activated or deactivated (see note
below).
P1 – P4 FullSet RDY
This output is activated when the partition is
ready to be activated.
P1 – P4 Part Set
This output is activated if a partition is internally
set.
P1- P4 FullSet
This output is activated if the partition is set.
Table 7: Output types
After configuring output name and type, you can wire the outputs of
wired outputs. You now have to teach the output for the radio outputs.