16.6 Testing Voltage Transformer for RECARO Seat
Testing Preparations
• Remove battery boxes. See chapter 12.1 in this connection.
• Remove splash protection. See chapter 11.7 in this connection.
• Install battery boxes.
Testing Voltage on Voltage Transformer for RECARO seat
• Detach plug connection from the battery cable to the
voltage transformer.
• Measure the voltage existing at the contacts of the feeder
cable (see drawing).
It must amount to at least 19 volts.
• Reconnect the plugs.
• Detach the plug connection to the RECARO seat.
• Measure the output voltage.
Depending on the charging status of the batteries, it must
amount to between 2.5 and 4 volts.

NOTE:
The voltage transformer provides an output voltage of 12 volts only under load
(seat connected and switched on). In conditions without load, only a level of
between 2.5 and 4 volts is to be measured.
CAUTION:
Malfunction
No voltage at the
feeder cable?
Voltage below 19 V?
Output voltage
higher than 4 volts and
lower than 2.5 volts?
90
Avoid by all means bridging the contacts of the power supply.
>Danger of Fire and Burning<.
Feeder cable defective.
Fuse (15 A) defective.
Power supply to the main module is
interrupted.
Battery fully discharged.
Voltage transformer defective.
Cause
Check / replace feeder cable.
Replace fuse.
Check voltage supply.
Check master fuse (50 A).
Pre-charge battery.
Replace battery.
Replace voltage transformer.
Main Module and Voltage Transformer
Fuse 15A
Plug of
feeder cable
Feeder : Testing Voltage
+
min. 19 volts
Remedy
Plug for

RECARO seat

V
Chapter
18.0
12.1
12.1
12.2
12.0
17.7