7 x Flashing
Battery fully discharged
8 x Flashing
Battery voltage too high
9 x Flashing
10x Flashing
11x Flashing
Compatibility problems
12x Flashing
* When the joystick box has just been switched on, the driving mode and the status display will flash additionally.
Error Message 10 km/h version only
Emergency flasher
continuously flashing
20
Error in data transfer
between modules
Drive motors
temporarily overloaded
between modules
Precharge / charge battery
Check battery charger
Check modules and programming,
inform INVACARE Service
Check plug and socket
connections plus BUS cable
Only in 10 km/h TÜV version: *
Fold rear light bar in driving
position (completely downwards)
Only in 10 km/h TÜV version: *
Check microswitch
replace if necessary
Switch joystick box off and on
again
Requires repair by
INVACARE Service
Loose or defective plug connection
to lighting module
Defective lighting module
Defective microswitch
Chapter 12.2
Chapter 12.3
Chapter 19.0
Chapter 18.0
Chapter 16.7
Chapter 18.0
Chapter 16.4
Chapter 16.7