■ Upload & Release a New Add-in
Uploads a new Add-in module and issues an update call as needed.
The new Add-in update module will be released, and applied to the scanners when the one of the
following occurs:
• Scanner is started, or resumed from the standby mode
• Scanner is logged out
• Scanner is notified of any update modules
Updates can be applied to the scanners that are in power-off or standby mode using Wake-On-
LAN.
If the Add-in module is already available, the module is replaced. However, if the date of the last
modified Add-in module version is the same as, or earlier than the currently available one, the
module cannot be uploaded.
• Upload an Add-in Module for the Add-in Group selected above.
Select the [Browse] button to specify the install module file.
Select the [Upload] button to upload the Add-in module.
• Issue an Update Call
Check the checkbox to issue an update call.
When the checkbox is selected, even if a scanner is not started or logged in to, the update
module is sent and applied to the scanner according to the Scanner Notification Schedule.
However, if the update is released while logged in to a scanner, the update will be applied
after logged out. If any other available updates are pending, those are also applied at the
same time.
• Scanner Notification Schedule
Sets the schedule to notify Add-in module.
• Now
Issues a call immediately.
• Later
Specifies the date and time to issue a call.
The default value is 00:00 of the following day. The value can be specified within the range
between the current time and a month later.
Update call schedule uses the Central Admin Server timezone.
• [Register] button
Registers the uploaded Add-in module to the selected Add-in group.
When a new Add-in module is available, it will only be not installed in a scanner
HINT
if both the name and version match that of the current Add-in. Scanners are
restarted twice when installing a new Add-in, once to uninstall the old Add-in,
and once again after the new Add-in has been installed.
Pending updates are performed in the following order:
1. System Updates
2. Add-in Installs
3. Scanner Settings

■ [Back] button

Returns to the Central Admin Console main window.