Step 2010-3; Step 2010-4; Step 2010-5; Step 2010-6 - IBM F80 Service Manual

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

3. If the problem remains, a software error has probably occurred. Call your support
center for assistance.

Step 2010-3

Have the system diagnostics or problem determination procedures given you a
5-digit SRN for the SSA hot-swap disk drive?
NO
YES

Step 2010-4

If the system diagnostics are available, go to "Step 2010-5."
If the stand-alone diagnostics are available, but the system diagnostics are not
available, run the stand-alone diagnostics, then go to "Step 2010-5."
If the system diagnostics and stand-alone diagnostics are not available, go to "Step
2010-1" on page 77.

Step 2010-5

Run the diagnostics in the problem determination mode.
Note: Do not run the advanced diagnostics, because errors are logged on other using
Did the diagnostics give you a 5-digit SRN for the SSA hot-swap disk drive?
NO
YES

Step 2010-6

Are all LEDs off on the drives in a 6 pack?
NO
YES

Step 2010-7

Are any power cables loose or in need of replacement?
NO
YES
78
Service Guide
If you do not get an SRN, the disk formatting may be incompatible with the
system (the disk was most likely formatted on a different type of using system).
1) Format the pdisk.
2) Issue the system cfgmgr command.
3) Retry the Configuration Verification service aid.
Go to "Step 2010-4."
Go to "Service Request Numbers (SRNs)" on page 427.
systems that share the same loop.
Go to "Step 2010-6."
Go to "Service Request Numbers (SRNs)" on page 427.
Go to step "Step 2010-9" on page 79.
Go to "Step 2010-7."
Go to "Step 2010-8" on page 79.
Fix or replace the power cables as required. Go to "MAP 410: Repair