IBM F80 Service Manual page 248

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
4B2A 300A
4B2A 300B
4B2A 300C
4B2A 300D
4B2A 300E
4B2A 301F
4B2A 303A
4B2B 244C
4B2B 244D
4B2B 244E
4B2B 244F
4B2B 248A
4B2B 24A1
4B2B 24A2
4B2B 24A3
4B2B 24A4
4B2B 25B6
230
Service Guide
Description
Processor system and self test
detected 32MB DIMM fault
Processor system and self test
detected 128MB DIMM fault
Processor system and self test
detected 256MB DIMM fault
Processor system and self test
detected 512MB (stacked) DIMM
fault
Processor system and self test
detected 512MB (unstacked) DIMM
fault
Processor system and self test
detected 128MB DIMM fault
Processor system and self test
detected 1GB DIMM fault
Processor system and wire test
detected 1W 2M 400 MHz processor
fault
Processor system and wire test
detected 2W 4M 500 MHz processor
fault
Processor system and wire test
detected 4W 4M 500 MHz processor
fault
Processor system and wire test
detected 1W 2M 500 MHz processor
fault
Processor system and wire test
detected operator panel fault
Processor system and wire test
detected 1W 2M 450 MHz processor
fault
Processor system and wire test
detected 2W 450 MHz processor
fault
Processor system and wire test
detected 4W 450 MHz processor
fault
Processor system and wire test
detected 6W 500 MHz processor
fault
Processor system and wire test
detected 650W power supply fault
Action/ Possible Failing FRU
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Operator panel, Location : L1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3

Advertisement