IBM F80 Service Manual page 254

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
4B2E 25B6
4B2E 25BB
4B2E 25BD
4B2E 25BE
4B2E 25BF
4B2E 25CB
4B2E 25EA
4B2E 25EB
4B2E 25F2
4B2E 263D
4B2E 281F
4B2E 282E
4B2E 283F
4B2E 288D
4B2E 2A00
4B2E 300A
4B2E 300B
4B2E 300C
236
Service Guide
Description
Processor system and scan control
routines detected 650W power supply
fault
Processor system and scan control
routines detected 1W 600 MHz
processor fault
Processor system and scan control
routines detected 2W 600 MHz
processor fault
Processor system and scan control
routines detected 4W 600 MHz
processor fault
Processor system and scan control
routines detected 6W 668 MHz
processor fault
1W processor card fault
4W processor card fault
2W processor card fault
6W processor card fault
Processor system and scan control
routines detected memory filler fault
Processor system and scan control
routines detected SSA backplane
fault
Processor system and scan control
routines detected system board fault
Processor system and scan control
routines detected SCSI backplane
fault
Processor system and scan control
routines detected memory riser fault
Processor system and scan control
routines detected 6W 4M 500 MHz
processor fault
Processor system and scan control
routines detected 32MB DIMM fault
Processor system and scan control
routines detected 128MB DIMM fault
Processor system and scan control
routines detected 256MB DIMM fault
Action/ Possible Failing FRU
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Memory riser card, Location: P1-M1
or P1-M2
Processor card, Location: P1-C1
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn

Advertisement

Table of Contents
loading

Table of Contents