IBM F80 Service Manual page 229

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
Description
4609 283F
I/O system and memory test detected
SCSI backplane fault
4609 288D
I/O system and memory test detected
memory riser fault
4609 2A00
I/O system and memory test detected
6W 4M 500 MHz processor fault
4609 300A
I/O system and memory test detected
32MB DIMM fault
4609 300B
I/O system and memory test detected
128MB DIMM fault
4609 300C
I/O system and memory test detected
256MB DIMM fault
4609 300D
I/O system and memory test detected
512MB (stacked) DIMM fault
4609 300E
I/O system and memory test detected
512MB (unstacked) DIMM fault
4609 301F
I/O system and memory test detected
128MB DIMM fault
4609 303A
I/O system and memory test detected
1GB DIMM fault
460A 244C
I/O system and self test detected 1W
2M 400 MHz processor fault
460A 244D
I/O system and self test detected 2W
4M 500 MHz processor fault
460A 244E
I/O system and self test detected 4W
4M 500 MHz processor fault
460A 244F
I/O system and self test detected 1W
2M 500 MHz processor fault
460A 248A
I/O system and self test detected
operator panel fault
460A 24A1
I/O system and self test detected 1W
2M 450 MHz processor fault
460A 24A2
I/O system and self test detected 2W
450 MHz processor fault
460A 24A3
I/O system and self test detected 4W
450 MHz processor fault
460A 24A4
I/O system and self test detected 6W
500 MHz processor fault
460A 25B6
I/O system and self test detected
650W power supply fault
460A 25BB
I/O system and self test detected 1W
600 MHz processor fault
Action/ Possible Failing FRU
SCSI 6-pack, Location: B1 or B2
Memory riser card, Location: P1-M1
or P1-M2
Processor card, Location: P1-C1
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Operator panel, Location : L1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Chapter 5. Error Code to FRU Index
211

Advertisement

Table of Contents
loading