3. If you have not already done so, remove the front, rear, and right side covers as
described in "Removing the Covers" on page 311.
4. Locate the next available fan position.
5. Pull the locking knob on the fan bay blank cover and remove it by pulling it straight
out from the system unit.
1
2
6. Install the new fan by pulling the locking knob out and then inserting the tabs on the
left side of the fan into the frame opening.
7. Swing the right side of the fan inward until the locking knob contacts the frame.
8. Push the locking knob until you feel it lock into position.
9. Go to "Installing a Redundant Power Supply" to install the redundant power supply.

Installing a Redundant Power Supply

Attention:
operate a new power supply in the top position.
1. Remove the power supply baffle plate from the redundant power supply by pulling
out the button and tilting the baffle out from the system.