Table 5. SPCN Error Codes (continued)
Error Code
Description
1011 7631
Missing fan 3
1011 7640
Fan 4 failure
1011 7641
Missing fan 4
1011 7650
Power supply 1 fan failure
1011 7651
Missing power supply 1 fan
1011 7660
Power supply 2 fan failure
1011 7661
Missing power supply 2 fan
1011 7670
Power supply 3 fan failure
1011 7671
Missing power supply 3 fan
1011 8400
VPD configuration problem
1011 8401
VPD access problem
1011 8402
VPD access problem
1011 8403
VPD level mismatch
1011 8404
Processor VPD mismatch
1011 8409
Processor VPD
1011 840A
VPD +5 stuck high
Action/ Possible Failing FRU
Fan 3, Location: F3
1. Fan 4
Location: F4
2. System board
Location: P1
Fan 4, Location: F4
1. Power supply 1
Location: V1
2. System board
Location: P1
Power supply 1, Location: V1
1. Power supply 2
Location: V2
2. System board
Location: P1
Power supply 2, Location: V2
1. Power supply 3
Location: V3
2. System board
Location: P1
Power supply 3, Location: V3
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1. Processor card, Location: P1-C1
2. System board, Location: P1
1. Ensure that the processor card is
the correct type for the system
and is properly installed.
2. Processor card, Location: P1-C1
Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
Chapter 5. Error Code to FRU Index
115

Advertisement

Table of Contents
loading

Table of Contents