Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
Description
406D 032D
Attention handler detected memory
DIMM fault
406D 0331
Attention handler detected memory
DIMM fault
406D 0332
Attention handler detected memory
DIMM fault
406D 033D
Attention handler detected memory
DIMM fault
406D 03FF
Attention handler detected memory
failure on processor card that cannot
be automatically isolated.
406D 3101
Attention handler detected RIO port 0
fault
406D 3281
Attention handler detected RIO port 0
fault
406D 3284
Attention handler detected PCI
controller PHB0 fault
406D 3285
Attention handler detected PCI
controller PHB1 fault
406D 3286
Attention handler detected PCI
controller PHB2 fault
406E 0001
Scan control routines detected
system board fault
406E 0003
Scan control routines detected
processor fault
406E 0009
Scan control routines detected
memory fault
406E 00A0
Scan control routines detected
service processor firmware fault
406E 00A1
Scan control routines detected
system firmware fault
406E 00A2
Scan control routines detected
service processor firmware (PRD)
fault
406E 00A3
Scan control routines detected
memory plugging fault
406E 00A4
Scan control routines detected
application caused fault
406E 00A5
Scan control routines detected invalid
system configuration
Action/ Possible Failing FRU
Memory DIMM Location: P1-C1-M3
x2
Memory DIMM Location: P1-C1-M5
Memory DIMM Location: P1-C1-M4
Memory DIMM Location: P1-C1-M4
x2
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
All processors, Location: P1-C1
Go to "MAP 1540: Minimum
Configuration" on page 57.
Update system firmware
1. Check for AIX updates
2. Check for system firmware
updates
Update system firmware
Go to "MAP 1540: Minimum
Configuration" on page 57.
Application software
Verify that system components are
supported and properly installed
Chapter 5. Error Code to FRU Index
175