Table 12. Service Request Numbers (continued)
SRN
FRU List
34000
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on page
324.)
External SSA cables
Internal SSA connections
SSA adapter card (See "Replacing
Adapter Cards" on page 332.)
40000
SSA adapter card (See the
installation guide and the service
guide for the using system.)
40016
through
42540
43PAA
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on page
324.)
SSA adapter card (See the
installation guide and the service
guide for the using system.)
44PAA
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on page
324.)
45PAA
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on page
324.)
External SSA Cables
6-pack assembly (See "Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays" on page 358.)
432
Service Guide
%
Problem
90
Description: The adapter cannot initialize a
device. This problem might be badly affecting the
SSA loop. If the device is part of a RAID array,
you may not be able to list this disk drive using
5
the RAID facilities.
5
Action: Replace the FRU with a new FRU.
100
Description: The SSA adapter card has failed.
Action: Exchange the FRU for a new FRU.
Action: Go to Advanced SerialRAID Adapters
User's Guide and Maintenance Information, order
number SA33-3285.
90
Description: An SSA device on the link is
preventing the completion of the link
configuration.
10
Action: If the SSA service aids are available, run
the Link Verification Service Aid to determine
which device is preventing configuration. (That
device is the one beyond the last-configured
device on an open SSA link.)
Run Set Service Mode on the failed pdisk.
Attempt to configure the failing device. If device
cannot be configured, replace the failing FRU.
100
Description: A disk drive module has failed.
Action: If the SSA service aids are available, run
the Link Verification Service Aid to find the failing
disk drive module.
Run Set Service Mode on the failed pdisk.
Before you exchange the failing disk drive
module, run diagnostics in the system verification
mode to the module to determine the cause of
the problem. Replace the indicated failing FRU.
40
Description: The SSA adapter has detected an
open SSA link. This problem is caused either by a
disk drive module that is failing, or by a disk drive
40
module that has been switched off from another
20
using system on the same SSA link. (That using
system has itself been switched off.)
Action: If the SSA service aids are available, run
the Link Verification Service Aid to determine
which device is preventing configuration. (That
device is the one beyond the last-configured
device on an open SSA link.) Attempt to configure
the failing device. If device cannot be configured,
replace the failing FRU.

Advertisement