Table 7. Service Processor Error Codes (continued)
Error Code
Description
4066 020E
Scan interface basic assurance tests
detected memory pair A fault
4066 0211
Scan interface basic assurance tests
detected memory DIMM fault
4066 0212
Scan interface basic assurance tests
detected memory DIMM fault
4066 0213
Scan interface basic assurance tests
detected memory DIMM fault
4066 0214
Scan interface basic assurance tests
detected memory DIMM fault
4066 021D
Scan interface basic assurance tests
detected memory DIMM fault
4066 0221
Scan interface basic assurance tests
detected memory DIMM fault
4066 0222
Scan interface basic assurance tests
detected memory DIMM fault
4066 0223
Scan interface basic assurance tests
detected memory DIMM fault
4066 0224
Scan interface basic assurance tests
detected memory DIMM fault
4066 022D
Scan interface basic assurance tests
detected memory DIMM fault
4066 0231
Scan interface basic assurance tests
detected memory DIMM fault
4066 0232
Scan interface basic assurance tests
detected memory DIMM fault
4066 0233
Scan interface basic assurance tests
detected memory DIMM fault
4066 0234
Scan interface basic assurance tests
detected memory DIMM fault
4066 023D
Scan interface basic assurance tests
detected memory DIMM fault
4066 02FF
Scan interface basic assurance tests
detected memory failure on riser card
1 that cannot be automatically
isolated.
4066 0300
Scan interface basic assurance tests
detected processor card fault
4066 0301
Scan interface basic assurance tests
detected memory DIMM fault
4066 0302
Scan interface basic assurance tests
detected memory DIMM fault
Action/ Possible Failing FRU
Memory Pair A, Location: P1-M1.1 x2
Memory DIMM Location: P1-M1.13
Memory DIMM Location: P1-M1.3
Memory DIMM Location: P1-M1.14
Memory DIMM Location: P1-M1.4
Memory DIMM Location: P1-M1.3 x4
Memory DIMM Location: P1-M1.11
Memory DIMM Location: P1-M1.5
Memory DIMM Location: P1-M1.12
Memory DIMM Location: P1-M1.6
Memory DIMM Location: P1-M1.5 x4
Memory DIMM Location: P1-M1.9
Memory DIMM Location: P1-M1.7
Memory DIMM Location: P1-M1.10
Memory DIMM Location: P1-M1.8
Memory DIMM Location: P1-M1.7 x4
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
Processor card Location: P1-C1
Memory DIMM Location: P1-C1-M8
Memory DIMM Location: P1-C1-M1
Chapter 5. Error Code to FRU Index