Table 7. Service Processor Error Codes (continued)
Error Code
Description
406B 020E
Wire tests detected memory pair A
fault
406B 0211
Wire tests detected memory DIMM
fault
406B 0212
Wire tests detected memory DIMM
fault
406B 0213
Wire tests detected memory DIMM
fault
406B 0214
Wire tests detected memory DIMM
fault
406B 021D
Wire tests detected memory DIMM
fault
406B 0221
Wire tests detected memory DIMM
fault
406B 0222
Wire tests detected memory DIMM
fault
406B 0223
Wire tests detected memory DIMM
fault
406B 0224
Wire tests detected memory DIMM
fault
406B 022D
Wire tests detected memory DIMM
fault
406B 0231
Wire tests detected memory DIMM
fault
406B 0232
Wire tests detected memory DIMM
fault
406B 0233
Wire tests detected memory DIMM
fault
406B 0234
Wire tests detected memory DIMM
fault
406B 023D
Wire tests detected memory DIMM
fault
406B 02FF
Wire tests detected memory failure
on riser card 1 that cannot be
automatically isolated.
406B 0300
Wire tests detected processor card
fault
406B 0301
Wire tests detected memory DIMM
fault
406B 0302
Wire tests detected memory DIMM
fault
Action/ Possible Failing FRU
Memory Pair A, Location: P1-M1.1 x2
Memory DIMM Location: P1-M1.13
Memory DIMM Location: P1-M1.3
Memory DIMM Location: P1-M1.14
Memory DIMM Location: P1-M1.4
Memory DIMM Location: P1-M1.3 x4
Memory DIMM Location: P1-M1.11
Memory DIMM Location: P1-M1.5
Memory DIMM Location: P1-M1.12
Memory DIMM Location: P1-M1.6
Memory DIMM Location: P1-M1.5 x4
Memory DIMM Location: P1-M1.9
Memory DIMM Location: P1-M1.7
Memory DIMM Location: P1-M1.10
Memory DIMM Location: P1-M1.8
Memory DIMM Location: P1-M1.7 x4
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
Processor card Location: P1-C1
Memory DIMM Location: P1-C1-M8
Memory DIMM Location: P1-C1-M1
Chapter 5. Error Code to FRU Index
165