Table 7. Service Processor Error Codes (continued)
Error Code
Description
460E 244D
I/O system and scan control routines
detected 2W 4M 500 MHz processor
fault
460E 244E
I/O system and scan control routines
detected 4W 4M 500 MHz processor
fault
460E 244F
I/O system and scan control routines
detected 1W 2M 500 MHz processor
fault
460E 248A
I/O system and scan control routines
detected operator panel fault
460E 24A1
I/O system and scan control routines
detected 1W 2M 450 MHz processor
fault
460E 24A2
I/O system and scan control routines
detected 2W 450 MHz processor
fault
460E 24A3
I/O system and scan control routines
detected 4W 450 MHz processor
fault
460E 24A4
I/O system and scan control routines
detected 6W 500 MHz processor
fault
460E 25B6
I/O system and scan control routines
detected 650W power supply fault
460E 25BB
I/O system and scan control routines
detected 1W 600 MHz processor
fault
460E 25BD
I/O system and scan control routines
detected 2W 600 MHz processor
fault
460E 25BE
I/O system and scan control routines
detected 4W 600 MHz processor
fault
460E 25BF
I/O system and scan control routines
detected 6W 668 MHz processor
fault
460E 263D
I/O system and scan control routines
detected memory filler fault
460E 281F
I/O system and scan control routines
detected SSA backplane fault
460E 282E
I/O system and scan control routines
detected system board fault
460E 283F
I/O system and scan control routines
detected SCSI backplane fault
Action/ Possible Failing FRU
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Operator panel, Location : L1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index