Table 1. Service Processor Checkpoints (continued)
Checkpoint
91FF
9380
94B0
94B1
94B2
94BB
9501
9502
9503
9504
9505
9506
99FD
99FF
A800
A801
A802
A803
A804
A805
A806
A807
A808
A809
A80A
A80B
A80C
A80D
A80E
A80F
B00B
88
Service Guide
Description
Control being handed to system
processor from service processor
Built-in-self-test (BIST)
Wire test faulty driver status
refcode
Wire test shorted net status refcode See note 2 on page 90
Wire test L2 cache status refcode
Wire test status SRC refcode
Main storage initialization
Main storage L3 cache march test
Main storage L3 connections test
Main storage L3 cache march test
MS extra testing (RIO, etc.)
MS cleanup
Service processor receiving
firmware update module
Service processor writing firmware
update module
Start Service Processor dump
process
Start dump to debug port
Start dump to debug port
NVRAM not usable
NVRAM dump done
Start dump to flash
Flash dump area done
Flash area not usable
Flash error log to debug port
Flash erase start
Flash erase end
Reserved; not used
Reserved; not used
Reserved; not used
Reserved; not used
Service processor dump done
Firmware delaying to determine if
MOPs error is the result of power
disturbance. After delay, SPCN is
queried for CEC power status.
Action/ Possible Failing FRU
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 2 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
See note 1 on page 90
1. Remove, then reapply power to
the system.
2. Call service support.