Table 7. Service Processor Error Codes (continued)
Error Code
Description
4B28 24A2
Processor system and other bus
processor runtime diagnostics
detected 2W 450 MHz processor
fault
4B28 24A3
Processor system and other bus
processor runtime diagnostics
detected 4W 450 MHz processor
fault
4B28 24A4
Processor system and other bus
processor runtime diagnostics
detected 6W 500 MHz processor
fault
4B28 25B6
Processor system and other bus
processor runtime diagnostics
detected 650W power supply fault
4B28 25BB
Processor system and other bus
processor runtime diagnostics
detected 1W 600 MHz processor
fault
4B28 25BD
Processor system and other bus
processor runtime diagnostics
detected 2W 600 MHz processor
fault
4B28 25BE
Processor system and other bus
processor runtime diagnostics
detected 4W 600 MHz processor
fault
4B28 25BF
Processor system and other bus
processor runtime diagnostics
detected 6W 668 MHz processor
fault
4B28 25CB
1W processor card fault
4B28 25EA
4W processor card fault
4B28 25EB
2W processor card fault
4B28 25F2
6W processor card fault
4B28 263D
Processor system and other bus
processor runtime diagnostics
detected memory filler fault
4B28 281F
Processor system and other bus
processor runtime diagnostics
detected SSA backplane fault
Action/ Possible Failing FRU
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index