IBM F80 Service Manual page 160

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
4066 030D
4066 0311
4066 0312
4066 031D
4066 0321
4066 0322
4066 032D
4066 0331
4066 0332
4066 033D
4066 03FF
4066 3101
4066 3281
4066 3284
4066 3285
4066 3286
4067 0001
4067 0003
4067 0009
4067 00A0
142
Service Guide
Description
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory DIMM fault
Scan interface basic assurance tests
detected memory failure on
processor card that cannot be
automatically isolated.
Scan interface basic assurance tests
detected RIO port 0 fault
Scan interface basic assurance tests
detected RIO port 0 fault
Scan interface basic assurance tests
detected PCI controller PHB0 fault
Scan interface basic assurance tests
detected PCI controller PHB1 fault
Scan interface basic assurance tests
detected PCI controller PHB2 fault
6xx bus processor runtime
diagnostics detected system board
fault
6xx bus processor runtime
diagnostics detected processor fault
6xx bus processor runtime
diagnostics detected memory fault
6xx bus processor runtime
diagnostics detected service
processor firmware fault
Action/ Possible Failing FRU
Memory DIMM Location: P1-C1-M1
x2
Memory DIMM Location: P1-C1-M7
Memory DIMM Location: P1-C1-M2
Memory DIMM Location: P1-C1-M2
x2
Memory DIMM Location: P1-C1-M6
Memory DIMM Location: P1-C1-M3
Memory DIMM Location: P1-C1-M3
x2
Memory DIMM Location: P1-C1-M5
Memory DIMM Location: P1-C1-M4
Memory DIMM Location: P1-C1-M4
x2
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
All processors, Location: P1-C1
Go to "MAP 1540: Minimum
Configuration" on page 57.
Update system firmware

Advertisement

Table of Contents
loading

Table of Contents