Table 7. Service Processor Error Codes (continued)
Error Code
Description
406A 0223
Self tests detected memory DIMM
fault
406A 0224
Self tests detected memory DIMM
fault
406A 022D
Self tests detected memory DIMM
fault
406A 0231
Self tests detected memory DIMM
fault
406A 0232
Self tests detected memory DIMM
fault
406A 0233
Self tests detected memory DIMM
fault
406A 0234
Self tests detected memory DIMM
fault
406A 023D
Self tests detected memory DIMM
fault
406A 02FF
Self tests detected memory failure on
riser card 1 that cannot be
automatically isolated.
406A 0300
Self tests detected processor card
fault
406A 0301
Self tests detected memory DIMM
fault
406A 0302
Self tests detected memory DIMM
fault
406A 030D
Self tests detected memory DIMM
fault
406A 0311
Self tests detected memory DIMM
fault
406A 0312
Self tests detected memory DIMM
fault
406A 031D
Self tests detected memory DIMM
fault
406A 0321
Self tests detected memory DIMM
fault
406A 0322
Self tests detected memory DIMM
fault
406A 032D
Self tests detected memory DIMM
fault
406A 0331
Self tests detected memory DIMM
fault
Action/ Possible Failing FRU
Memory DIMM Location: P1-M1.12
Memory DIMM Location: P1-M1.6
Memory DIMM Location: P1-M1.5 x4
Memory DIMM Location: P1-M1.9
Memory DIMM Location: P1-M1.7
Memory DIMM Location: P1-M1.10
Memory DIMM Location: P1-M1.8
Memory DIMM Location: P1-M1.7 x4
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
Processor card Location: P1-C1
Memory DIMM Location: P1-C1-M8
Memory DIMM Location: P1-C1-M1
Memory DIMM Location: P1-C1-M1
x2
Memory DIMM Location: P1-C1-M7
Memory DIMM Location: P1-C1-M2
Memory DIMM Location: P1-C1-M2
x2
Memory DIMM Location: P1-C1-M6
Memory DIMM Location: P1-C1-M3
Memory DIMM Location: P1-C1-M3
x2
Memory DIMM Location: P1-C1-M5
Chapter 5. Error Code to FRU Index