Table 9. Common Firmware Error Codes (continued)
Error Code
Description
B10F 1681
Service processor firmware update
invalid
B10F 1682
Service processor firmware update
invalid
B10F 1683
Service processor firmware update
invalid
B1FD 0013
A firmware update has failed because
the update image is invalid. The
update was aborted before any
changes were made to the currently
installed firmware.
B1FD 0015
Too many firmware update diskettes
inserted (or wrong or faulty update
image)
B1FD 0016
Diskette read error
B1FD 001A
Service processor recovery mode
update fault
B1FD 001E
Service processor recovery mode
update fault
B1FD 001F
Bad firmware update diskette
B1xx 0013
A firmware update has failed because
the update image is invalid. The
update was aborted before any
changes were made to the currently
installed firmware.
B1xx 4600
Service processor failure
B1xx 4601
System processor subsystem
B1xx 4602
RIO subsystem failure
B1xx 4603
Service processor firmware corrupted 1. Reload system firmware
Action/ Possible Failing FRU
Call service support
Call service support
Call service support
Reset the service processor (by
activating the pinhole reset switch or
by disconnecting then reconnecting
power). Install a valid firmware
update image for the specific system
type and model.
1. Ensure that the firmware update
image is correct for the specific
system type and model.
2. Replace the update diskettes with
a new set of firmware update
diskettes.
1. The firmware diskette may be
faulty. Try another diskette.
2. Replace the diskette drive.
3. Replace the system board
Location: P1
Reset the service processor by
activating the pinhole reset switch or
by disconnecting and then
reconnecting the power.
Wrong firmware update diskette.
Insert correct diskette.
Replace diskette
Install a valid firmware update image
for the specific system type and
model.
System board, Location: P1
Go to "MAP 1540: Minimum
Configuration" on page 57
1. Processor card, Location: P1-C1
2. Replace the system board,
Location: P1 (See note 3 on page
41.)
2. Replace the system board,
Location: P1 (See note 3 on page
41.)
Chapter 5. Error Code to FRU Index
241