Table 7. Service Processor Error Codes (continued)
Error Code
Description
406F 0233
Error code generation/logging
detected memory DIMM fault
406F 0234
Error code generation/logging
detected memory DIMM fault
406F 023D
Error code generation/logging
detected memory DIMM fault
406F 02FF
Error code generation/logging
detected memory failure on riser card
1 that cannot be automatically
isolated.
406F 0300
Error code generation/logging
detected processor card fault
406F 0301
Error code generation/logging
detected memory DIMM fault
406F 0302
Error code generation/logging
detected memory DIMM fault
406F 030D
Error code generation/logging
detected memory DIMM fault
406F 0311
Error code generation/logging
detected memory DIMM fault
406F 0312
Error code generation/logging
detected memory DIMM fault
406F 031D
Error code generation/logging
detected memory DIMM fault
406F 0321
Error code generation/logging
detected memory DIMM fault
406F 0322
Error code generation/logging
detected memory DIMM fault
406F 032D
Error code generation/logging
detected memory DIMM fault
406F 0331
Error code generation/logging
detected memory DIMM fault
406F 0332
Error code generation/logging
detected memory DIMM fault
406F 033D
Error code generation/logging
detected memory DIMM fault
406F 03FF
Error code generation/logging
detected memory failure on
processor card that cannot be
automatically isolated.
406F 3101
Error code generation/logging
detected RIO port 0 fault
406F 3281
Error code generation/logging
detected RIO port 0 fault
Action/ Possible Failing FRU
Memory DIMM Location: P1-M1.10
Memory DIMM Location: P1-M1.8
Memory DIMM Location: P1-M1.7 x4
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
Processor card Location: P1-C1
Memory DIMM Location: P1-C1-M8
Memory DIMM Location: P1-C1-M1
Memory DIMM Location: P1-C1-M1
x2
Memory DIMM Location: P1-C1-M7
Memory DIMM Location: P1-C1-M2
Memory DIMM Location: P1-C1-M2
x2
Memory DIMM Location: P1-C1-M6
Memory DIMM Location: P1-C1-M3
Memory DIMM Location: P1-C1-M3
x2
Memory DIMM Location: P1-C1-M5
Memory DIMM Location: P1-C1-M4
Memory DIMM Location: P1-C1-M4
x2
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
Chapter 5. Error Code to FRU Index