IBM F80 Service Manual page 383

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

4. Connect the power cables to the power connectors, which are located on the
system board behind the enclosure. The following diagram shows the right side of
the system with the cover removed.
7
6
5
4
3
2
1
1
I2C to DASD Bay 1 (DB1)
2
Power 2 to DASD Bay 1 (DB1)
3
Power 1 to DASD Bay 1 (DB1)
4
Power 1 to DASD Bay 2 (DB2)
5
Power 2 to DASD Bay 2 (DB2)
6
I2C to DASD Bay 2 (DB2)
7
Power to diskette drive
8
Power to DASD 2-pack or media device
9
Power to DASD 2-pack or media device
5. Connect the signal cables. Refer to "SCSI and SSA Cabling Configurations" on
page 366, and follow the cabling diagram for your system configuration.
6. Slide the disk drive cage all the way into the system unit until it contacts the front
frame.
7. Install six screws to hold the disk drive cage in the system unit. There are four
screws in the front of the unit and two inside the back (one at the upper left, one at
the lower right). Use the long nut driver provided with the disk drive cage to install
the screws.
8. Install the disk drives in the disk drive cage you just installed. Refer to "Replacing
Hot-Plug SCSI Disk Drives" on page 321.
9. Replace the covers as described in "Replacing Covers" on page 314.
8
9
Chapter 9. Removal and Replacement Procedures
365

Advertisement