Spcn Error Codes - IBM F80 Service Manual

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

SPCN Error Codes

Attention:
the AIX error log. If the system has to be shut down to replace a power supply or fan,
reboot the system, wait five minutes after the AIX login prompt appears, then recheck
the AIX error log. If the detailed information for the most recent error with the same
identifier indicates that the original problem has not been fixed by performing the first
action in the action column, continue with the next action in the action column.
Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 57 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to "MAP
410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 5. SPCN Error Codes
Error Code
1011 00AC
1011 00EF
1011 1510
1011 1511
1011 1512
110
Service Guide
If a power supply or fan is hot-swapped, wait five minutes, then recheck
If you replace FRUs or perform an action and the problem is still not
Description
ac loss or brownout detected
Room emergency power off detected
Power supply 1 ac source failure
Power supply 1
Power supply 1
Action/ Possible Failing FRU
Information message
Information message
1. Check power input to power
supply.
2. Power supply, Location: V1
3. System board, Location: P1
1. Power supply 1,
Location: V1
2. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 2, location V2, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V2. Then replace power
supply 3 (if present), location V3,
with the new supply.
4. Replace the system board
Location: P1
1. Power supply,
Location: V1
2. System board
Location: P1