Mounting an EX2200 Switch in a Recessed Position in a Rack or Cabinet

Related
Documentation

Mounting an EX2200 Switch on a Wall

Mounting an EX2200 Switch Except the EX2200-C Model on a Wall

88
Mounting an EX2200 Switch in a Recessed Position in a Rack or Cabinet on page 88
Rack-Mounting and Cabinet-Mounting Warnings on page 167
You can mount an EX2200 switch except the EX2200-C switch model in a rack or cabinet
such that the switch is recessed inside the rack from the rack front by 2 inches. You can
use the 2-in.-recess front brackets provided in the separately orderable four-post
rack-mount kit to mount the switch in a recessed position.
Reasons that you might want to mount the switch in a recessed position include:
You are mounting the switch in a cabinet and the cabinet doors will not close completely
unless the switch is recessed.
The switch you are mounting has transceivers installed in the uplink ports—the
transceivers in the uplink ports protrude from the front of the switch.
To mount the switch in a recessed position on four posts, follow the instructions in
"Mounting an EX2200 Switch on Four Posts of a Rack or Cabinet" on page
the switch in a recessed position on two posts, follow the instructions in
EX2200 Switch on Two Posts of a Rack or Cabinet" on page
Connecting Earth Ground to an EX Series Switch on page 103
Rack-Mounting and Cabinet-Mounting Warnings on page 167
This topic describes the process of mounting an EX2200 switch on a wall.
Mounting an EX2200 Switch Except the EX2200-C Model on a Wall on page 88
1.
2.
Mounting an EX2200-C Switch on a Wall on page 91
You can mount an EX2200 switch on a wall by using the separately orderable wall-mount
kit.
WARNING:
When mounting an EX2200 switch chassis in a vertical position, orient the
front panel of the chassis downward to ensure proper airflow and meet
safety requirements in the event of a fire.
When wall mounting Power over Ethernet (PoE) models (EX2200-24P
and EX2200-48P), install the wall-mount baffle above the units to reduce
the risk of objects or substances falling into the air exhaust or power supply,
which could cause a fire.
84. To mount
"Mounting an
81.