Performing Initial Configuration; Ex2200 Switch Default Configuration - Juniper EX2200 Series Hardware Manual

Juniper networks switch user manual
Hide thumbs Also See for EX2200 Series:
Table of Contents

Advertisement

CHAPTER 11

Performing Initial Configuration

EX2200 Switch Default Configuration

Copyright © 2011, Juniper Networks, Inc.
EX2200 Switch Default Configuration on page 125
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 129
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 131
Each EX Series switch is programmed with a factory default configuration that contains
the values set for each configuration parameter when a switch is shipped. The default
configuration file for an EX2200 switch configures Ethernet switching and storm control
on all interfaces, configures Power over Ethernet (PoE) on all interfaces of models that
provide PoE, and enables the LLDP, LLDP-MED, and RSTP protocols and IGMP snooping.
When you commit changes to the configuration, a new configuration file is created that
becomes the active configuration. You can always revert to the factory default
configuration—because an EX2200 switch does not have an LCD panel, use the CLI
commands to revert to the factory default configuration. See Reverting to the Default
Factory Configuration for the EX Series Switch.
The following factory default configuration file is for an EX2200 switch with 24 ports, all
of which have PoE capability:
NOTE:
The factory default configuration file is different for different EX2000
switch models.
The number of interfaces in the default configuration file depends on the
number of ports in the EX2200 switch.
The
poe
stanza does not appear for models without PoE.
Uplink ports for the EX2200 switches except the EX2200-C models will be
listed as
ge-0/1/0
ge-0/1/1
.
system {
syslog {
user * {
any emergency;
to
and for the EX2200-C switches as
ge-0/1/3
to
ge-0/1/0
125

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents