2

Laser safety

This system is equipped with a laser. If the system is operated in
accordance with the instructions in this manual, the laser poses no
possibility of danger.
The laser radiation is completely confined within the machine housing.
The laser beam cannot escape the housing at any time of operation.
This system is certified as a Class 1 laser product. This means that the
system does not generate any hazardous laser radiation.

Internal Laser Radiation

Mean radiation output:
340 µW at the laser opening of the printer head.
Wave length: 775-800 nm
This system operates using a Class IIIb laser diode that emits an invisible
laser beam. The laser diode and scanning polygon mirror are incorporated
in the print head unit.
The print head unit is NOT A FIELD SERVICE ITEM. It may not be opened
under any circumstances.
Print head
The above illustration indicates the location of the print head of the
system.
This is a semiconductor laser system. The maximum radiation capacity of
the laser diode is 15 mW. The wavelength is 775-800 nm.