Advertisement

Figure 39
QPC757 option and PRI/ISL low-speed programming switch settings
Port address switch settings
Table 27 "D-channel port address switch settings for PRI" (page 89)
the port address switch settings that apply to SW1, SW2 (the D-channel
port), SW3, and SW4.
Table 27
D-channel port address switch settings for PRI
Port Number
J1
0
2
4
6
8
10
12
14
Copyright © 2003-2007, Nortel Networks
.
J2
1
2
5
7
9
11
13
15
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
Port Address Switch Settings
SW1
SW2
Off
Off
Off
Off
Off
On
Off
On
On
Off
On
Off
On
On
On
On
Install the QPC757 DCH 89
shows
SW3
SW4
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
Off