280 2.0 Mb PRI implementation
Prompt
Response
ttt
PERS
ttt
CLRS
nnn
OOSC
LD 73 - Changing trunk pad category values
Prompt
Response
REQ
CHG
TYPE
PRI2
FEAT
PADS
#
PDCA
The following prompts define the pad levels.
The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15.
The pad values (in decibels) relating to these codes are shown after this table.
r t
ONP
r t
DSET
r t
OPX
DTT
r t
r t
SDTT
r t
NTC
TRC
r t
r t
DCO
r t
VNL
DTO
r t
r t
ACO
r t
AFX
ADD
r t
r t
SATT
r t
ATO
PRI2
r t
Copyright © 2003-2007, Nortel Networks
.
Description
Persistence Timer for Group II problems.
Enter 0-256 msec in increments of 2 msec. Default is 50
(=100ms).
Clearance Timer for Group II problems. Enter 0 - 256 msec in
increments of 2 msec. Default is 50 (=100ms).
Out-of-Service Counter.
Range for nnn of 0-255 with a default of 5.
Description
Change data.
2.0 Mb PRI.
PAD table-0 is default and is hard coded.
On-premises extension.
Meridian Digital set.
Prompted only if the 2.0 Mb Gateway feature is equipped.
Off-premises extension.
Digital TIE trunks.
Digital Satellite TIE trunks.
Nontransmission compensated.
Transmission compensated.
Digital COT, FEX, WAT, and DID trunks.
Via Net Loss.
2.0 Mb PRI2 digital TOLL office trunks.
Analog CO or WATS trunks.
Analog FEX trunks.
Analog DID trunks.
Analog satellite TIE trunks.
Analog TOLL office trunks.
2.0 Mb PRI trunk.
Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=2.0 Mb PRI.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007