248 2.0 Mb DTI implementation
Prompt
Response
r t
ONP
r t
OPX
TNLS
YES (NO)
DFLT
(1)-16
The following prompts define the pad levels.
The receiving pad code is r and the transmission pad code is t. These entries have the range 0-15.
The pad values (in decibels) relating to these codes are shown after this table.
r t
ONP
r t
OPX
r t
DTT
r t
SDTT
r t
NTC
r t
TRC
r t
DCO
r t
VNL
r t
DTO
r t
ACO
r t
AFX
r t
ADD
r t
SATT
r t
ATO
r t
DTI2
r t
XUT
r t
XEM
The following pads are available for the 2.0 Mb DTI card. Their respective
codes are also given. Positive dB represents loss and negative dB
represents gain.
Copyright © 2003-2007, Nortel Networks
.
Description
On-premises extension.
Off-premises extension.
TN List. This is for the print command only.
A YES response means that a list of the trunk TNs using the
requested PAD category tables are printed after the table.
For NEW only. The table is used for default values.
On-premises extension.
Off-premises extension.
Digital TIE trunks.
Digital Satellite TIE trunks.
Nontransmission compensated.
Transmission compensated.
digital COT, FEX, WAT, and DID trunks.
Via Net Loss.
2.0 Mb DTI digital TOLL office trunks.
Analog CO or WATS trunks.
Analog FEX trunks.
Analog DID trunks.
Analog satellite TIE trunks.
Analog TOLL office trunks.
2.0 Mb DTI trunk
(Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=DTI2).
Analog CO trunk
(Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=DTI2).
Analog TIE trunk
(Prompted only if the 1.5/2.0 Mb Gateway feature is equipped
and TYPE=DTI2).
Nortel Communication Server 1000