Nortel 1000 Installation And Commissioning Manual page 249

Isdn primary rate interface
Table of Contents

Advertisement

Table 90
2.0 Mb DTI pads
code
0
0.0
value (dB)
8
code
+8.0
value (dB)
code
16
value (dB)
-2
code
24
value (dB)
-10
LD 73 - Defining the 2.0 Mb DTI timers
Prompt
Response
REQ
NEW
CHG
TYPE
DTI2
FEAT
LPTI
xx
LOOP
P DIGT (S)
abcd
N
P METR(R)
abcd
N
EDGE
0
1
TIME
40-(240)-480
SASU
0-(1920)-8064
Copyright © 2003-2007, Nortel Networks
.
1
2
+1.0
+2.0
9
10
+9.0
+10.0
17
18
-3
-4
25
26
+0.6
idle
Description
Add or Change Digital Trunk Interface data block
2.0 Mb DTI
Set the timers used for a 2.0 Mb DTI
2.0 Mb DTI card slot number.
xx = 1-9 in Main Cabinet.
xx = 11-19, 21-29, 31-39, 41-49 in IP expansion cabinets
1-4, respectively.
xx = 11-14, 21-24, 31-34, 41-44 of the first, second, third and
fourth Media Gateway, respectively.
Digit pulse timing from TDS (Bits P, X or U are selectable)
If DIGT(S) signal not required
Metering (receive). Bits P, X or U. Only two P bits allowed.
COT and DID trunks only.
Note: PPM package must be enabled.
If METR(R) signal not required
PPM bit counted when changed from 1 to 0.
PPM bit counted when changed from 0 to 1.
Maximum time METR signal is in milliseconds.
Seize acknowledge supervision period in milliseconds.
2.0 Mb DTI default = 1920
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
DTI software implementation 249
3
4
5
+3.0
+4.0
+5.0
11
12
13
+11.0
+12.0
+13.0
19
20
21
-5
-7
-6
6
7
+6.0
+7.0
14
15
+14.0
-1
22
23
-8
-9

Advertisement

Table of Contents
loading

Table of Contents