Nortel 1000 Installation And Commissioning Manual page 246

Isdn primary rate interface
Table of Contents

Advertisement

246 2.0 Mb DTI implementation
Prompt
Response
TIME
64-(128)-192
N
P CAS(R)
abcd
N
CLRB(R)
abcd
N
P RCTL(R)
abcd
N
TIME
96-(128)-320
96-(256)-320
P NXFR(R)
abcd
N
P ESNW(R)
abcd
N
P CAS(R)
abcd
N
CLRF(S)
abcd
N
TIME
(0)
SOSO
abcd (N)
LD 73 - Defining the 2.0 Mb DTI pad tables
Prompt
Response
REQ
NEW
CHG
TYPE
DTI2
FEAT
PAD
Copyright © 2003-2007, Nortel Networks
.
Description
Length of BURS(R) pulse in milliseconds.
If SEZV(S) not required.
CAS Flash. Same timing as analogue trunks. Prompted for
JDMI only. Operational only if CASR package equipped.
If CAS(R) not required.
Clear back.
If CLRB(R) not required, when IDLE is used.
Release control. Prompted only when CLRB is unused or is
defined the same as IDLE.
If RCTL(R) not required.
Time value stored in multiples of 8 milliseconds.
Network transfer.
If not required.
ESN wink signal.
If ESNW(R) not required.
Centralized attendant service signal.
2.0 Mb DTI only
If CAS(R) not required.
Clear forward (send).
If CLRF(S) not required.
800 milliseconds.
Note: Prompted when the abcd bits entered in response to the
CLFR(S) prompt are different from the abcd bits of the IDLE
signal.
Special operator signal defined (undefined).
Note: Prompted when OPRC = N.
Description
Add or change Digital Trunk Interface data block.
2.0 Mb DTI.
Request the digital pad feature.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
3
.

Advertisement

Table of Contents
loading

Table of Contents