Isdn primary rate interface
Table of Contents

Advertisement

Prompt
Response
COT
WAT
DID
TIE
FEX
DTRK
YES
LD 14 - Configuring the trunks
Prompt
Response
REQ
NEW
CHG
xxx
TYPE
TN
l ch
0-511 1-4000
RTMB
0-127 1-4000
LD 73 - Assigning a clock reference source
Prompt
Response
REQ
CHG
TYPE
DDB
xx
CCO
xx
PREF CCO
xx
SREF CCO
xx
CC1
xx
PREF CC1
xx
SREF CC1
xx
CC2
xx
PREF CC2
xx
SREF CC2
CC3
xx
xx
PREF CC3
Copyright © 2003-2007, Nortel Networks
.
Description
Central Office Trunk data block WATS Trunk data block
Direct Inward Dial Trunk data block TIE Trunk data block
Foreign Exchange
Digital trunk route.
Description
Add new data.
Change existing data.
Trunk type
Loop and channel for digital trunks
Route number and Member number
Range for Large System and CS 1000E system.
Range for Meridian 1 Small System, Media Gateway
1000B.
Description
Change existing data.
Digital Data Block.
Card slot number for Clock Controller 0.
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number of PRI/DTI/SILC containing the primary clock
reference for the main cabinet
Card number for Clock Controller 1.
Primary Reference DTI/PRI loop for Clock controller one.
Primary Reference DTI/PRI loop for Clock controller one.
Card number for Clock Controller 2.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC
containing the primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC
containing the primary clock reference.
Card number for Clock Controller 3.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC
containing the primary clock reference.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007