LD 17 - Adding a D-channel interface
Prompt
Response
REQ
CHG
TYPE
ADAN
- ADAN
NEW DCH xx
CHG DCH xx
OUT DCH xx
- CTYP
DCHI
MSDL
TMDI
1-50
- CDNO
- PORT
1
- DES
<CR>
- USR
PRI
xx
- IFC
- - DCHL
xx
- OTBF
1-(16)-127
- DRAT
64KC
- SIDE
NET (USR)
xx
- RLS
- RCAP
ND2
- OVLR
YES (NO)
Copyright © 2003-2007, Nortel Networks
.
Description
Change existing data.
Action Device And Number.
Add a primary D-channel (any unused SDI port.)
Change a primary D-channel.
Remove the primary D-channel, where:
xx =0-79.
DCHI = D-channel configuration for the NTAK09 card or
NTAK93.
MSDL = NTBK51 Downloadable D-channel daughterboard.
TMDI = D-channel configuration on TMDI (NTRB21) card.
Card slot number to be used as the primary DDCH/DCHI.
Card slots 10, 20, 30, 40, and 50 are only applicable for
D-channel configuration of ISL or VNS.
PORT must be set to 1.
Designator.
D-channel is for ISDN PRI only.
Interface type.
PRI loop number.
Number of output request buffers.
Note: For a single PRI link, leave this prompt at default (16).
Add 5 output request buffers per additional link.
D-channel transmission rate.
Prompted only if IFC is set to SL1.
NET = network, the controlling switch.
USR = slave to the controller.
Release ID of the switch at the far-end of the D-channel.
Remote capability.
Allow or disallow overlap receiving on a D-channel. Default
is NO. Enter carriage return if settings are to be left at
default.