278 2.0 Mb PRI implementation
Prompt
Response
xx
PREF CC3
xx
SREF CC3
xx
CC4
xx
PREF CC4
xx
SREF CC4
CCAR
0-(15)
LD 73 - Defining PRI parameters and thresholds
Prompt
Response
REQ
CHG
TYPE
PRI2
FEAT
LPTI
LOOP
X
MFF
AFF (CRC)
ALRM
(REG) ALT
G10S
mc mt oc ot
SLP
BPV
n1 n2
Copyright © 2003-2007, Nortel Networks
.
Description
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
Card number for Clock Controller 4.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
Card number of PRI/DTI/SILC or DTI2/PRI2/SILC containing the
primary clock reference.
Clock Controller Audit Rate. Enter the time (in minutes) between
normal CC audits.
Description
Change data.
2.0 Mb PRI.
Loop timers.
X is the slot number of the 2.0 Mb PRI card.
Alternate mode or CRC multiframe mode.
Default or alternate alarms selected.
Slip error count.
where
mc = Maintenance threshold slip count, 1- (5)-255.
mt = Maintenance threshold time, default 24 hours.
oc = Out-of-service threshold slip count, 1-(30)-255.
ot = Out-of-service threshold time, default 1 hour.
Bipolar violation error count. Range is 1-(128)-255 for n1,
1-(122)-255 for n2.
where
n1 is multiplied by 16 to obtain the actual count, giving an
actual count range of 16-4080.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007