298 Nonstandard cables
From
P1-11
P1-12
P1-13
P1-14
P1-15
QCAD129
This cable is used to connect the RS-232-C interface between an echo
canceller and the PRI pack.
•
•
•
•
Table 110
QCAD129 wire list
PRI Signal
DCD
RXD
DTR
TXD
GND
RTS
CTS
TPENB
(Test Port
Enable Bar)
QCAD133
For cabinets with an I/O filter assembly, this cable transports the T1 signal
from the I/O filter to the Network Channel Terminating Equipment (NCTE)
telephone company interface. See Table
(page
Copyright © 2003-2007, Nortel Networks
.
To
P2-11
P2-12
P2-13
P2-14
P2-15
Standard length - 2.1 m (7 ft.)
Construction - 22 AWG (0.644 mm), stranded
P1 Connector - 15-pin, male, subminiature D, with jackscrews
P2 connector - 25-pin, male, subminiature D, with jackscrews
From
P1-10
P1-12
P1-15
299).
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
Signal
RRING (receive ring) from telephone
company
P1-1
P2-20
P1-2
P2-2
P1-4
P2-8
P1-5
P2-3
P2-7
P2-4
P1-9
P2-5
Table 111 "QCAD133 wire list"
Echo
Canceller
To
Signal
DTR
TXD
DCD
RXD
GND
nc