Nortel 1000 Installation And Commissioning Manual page 245

Isdn primary rate interface
Table of Contents

Advertisement

Prompt
Response
N
CLRF(R)
abcd
N
SOSI
abcd
(N)
Outgoing Calls:
SEZA(S)
abcd
SEZD(S)
abcd
N
SEZV(S)
abcd
xxx yyy
TIME
N
SEZA(R)
abcd
N
P WNKS(R)
abcd
N
TIME
20-(140)-500,
20-(290)-500
P EOS(R)
abcd
N
TIME
(64)-320
64-(256)-320
CONN(S)
abcd
CONN(R)
abcd
P OPRC(R)
abcd
N
P BURS(S)
abcd
N
P BURS(R)
abcd
N
Copyright © 2003-2007, Nortel Networks
.
Description
If CAS(S) not required.
Clear forward (receive).
If CLRF(R) not required.
Special operator signal defined.
Undefined. Prompted when OPRC = N.
Seize acknowledgement
Seize acknowledgement and (send) data signal.
If SEZD(S) not required.
Seize acknowledgement and (send) voice signal. Only
recommended for Meridian to M-1 applications.
Minimum and maximum time range for OPRS(R) in milliseconds.
xxx = 8-(48)-2040
yyy = xxx-(128)-2040
If SEZV(S) not required.
Seize acknowledgment (receive) signal.
If SEZA(R) not required.
Wink start pulsed seize acknowledgment (receive) signal.
If P WNKS(R) not required.
Minimum and maximum length of WNKS(R) pulse in
milliseconds.
End of selection (receive) signal.
If EOS(R) not required.
Length of EOS(R) pulse stored in multiples of 8 milliseconds.
Connect send.
Connect receive.
Operator recall signal for special services. minimum three
pulses of 160 milliseconds each.
If OPRC(R) not required.
Bring up receiver (send) for L1 networking.
If BURS(S) not required.
Bring up receiver (receive) for L1 networking.
If BURS(R) not required.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
DTI software implementation 245