Introduction; Nt5K40Aa, Nt5K41Aa, Nt5K86Aa; Nt8D7206, Nt8D7207 - Nortel 1000 Installation And Commissioning Manual

Isdn primary rate interface
Table of Contents

Advertisement

296 Nonstandard cables
"NTND27 MSDL to I/O panel cables" (page 303)
"NTND98 PRI to I/O panel cables" (page 303)

Introduction

This section provides information required to build systems cables of
nonstandard lengths for ISDN PRI applications.

NT5K40AA, NT5K41AA, NT5K86AA

These cables are used to transport the 2Mb digital signal from the faceplate
connector on the PRI card to the Line Terminating Equipment interface.
Table 107
NT5K40AA, NT5K41AA, NT5K86AA wire list
From
(pack end)
J1-1
J1-9
J1-3
J1-11
J1-9

NT8D7206, NT8D7207

This cable is used to transport the 2Mb/s digital signal from the PRI pack to
the I/O assembly located at the cabinet bulkhead.
Copyright © 2003-2007, Nortel Networks
.
Standard lengths:
— NT5K40AA - 4 m (13 ft.)
— NT5K41AA - 8 m (26 ft.)
— NT5K86AA - 12m (39 ft.)
Construction - 75 ohm dual co-axial type with solid inner conductor and
braided shield.
J1 Connector - 15-pin, male, subminiature D with jackscrews
J2 Connector - 75 ohm BNC crimp plug
J3 Connector - 75 ohm BNC crimp plug
To
(I/O end)
J2 Inner Conductor
J2 Shield
J3 Inner Conductor
J3 Shield
J3 Shield
Standard length -
3.05 m (10 ft.) for Half Group systems and Single group systems
Construction - 24 AWG, stranded foil-shielded twisted pairs
P1 Connector (Pack end) - 9-pin, male, subminiature D, with jackscrews
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
Signal
XTIP (transmit)
XRING (transmit)
RTIP (receive)
RRING (receive)
FRAME GROUND