Nt5D12 Switch Settings; Nortel Communication Server - Nortel 1000 Installation And Commissioning Manual

Isdn primary rate interface
Table of Contents

Advertisement

Note in all cases - If a QPC720 card is being replaced by a DDP card, the
D-channel Handler or MSDL can be either reconnected to the DDP card, or
removed if an onboard NTBK51AA DDCH card is used.

NT5D12 switch settings

The NT5D12 card is equipped with 6x2 sets of DIP switches for trunk
parameters settings for port0 and port1 respectively. Additionally, the
NT5D12 card is equipped with one set of four DIP switches for the Ring
Ground setting and one set of eight DIP switches for the D-channel Handler
parameters setting.
The DIP switches are used for setting of default values of certain
parameters. The general purpose switches are read by the firmware which
sets the default values accordingly.
The following parameters are being set by the DIP switches. Factory setups
are shown in bold.
General Purpose Switches
A per-trunk set of four DIP switches provides the default setting for
operational modes. Switch set S9 is used for Trunk 0. Switch set S15 is used
for Trunk 1. Refer to
Table 55
General purpose switch settings
Switch
1
2
3
4
Trunk interface switches
Transmission Mode
A per-trunk switch provides selection for T1 transmission. See
"Trunk interface transmission mode switch settings" (page
Copyright © 2003-2007, Nortel Networks
.
Table 55 "General purpose switch settings" (page
Description
Framing Mode
Yellow Alarm Method
Zero Code Suppression
Mode
Unused

Nortel Communication Server 1000

ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
NT5D12 switch settings 145
S9/S15 Switch Setting
OFF - ESF
ON - SF
OFF - FDL
ON - Digit2
OFF - B8ZS
ON - AMI
OFF
Table 56
146).
145)'.