• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See Chapter 8 "Parts listing, TD200 Machine Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836" on page
257 to determine which components are customer replaceable units (CRU) and which components are
field replaceable units (FRU).
• If an action step is preceded by "(Trained service technician only)," that step must be performed only by
a trained service technician.
A bus timeout has occurred
on system %1.(%1 =
CIM_ComputerSystem.ElementName)
The System %1 encountered
a POST Error.(%1 =
CIM_ComputerSystem.ElementName)
The System %1 encountered
a POST Error.(%1 =
CIM_ComputerSystem.ElementName)
38
ThinkServer TD200 Hardware Maintenance Manual
Error
A bus timeout has occurred.
Error
A POST error has
occurred.(Sensor = ABR
Status)
Error
A POST error has
occurred.(Sensor = Firmware
Error)
1. Remove the adapter from the
PCI slot that is indicated by a
lit LED.
2. Replace the extender card.
3. Remove all PCI adapters.
4. (Trained service technicians
only) Replace the system
board.
1. Make sure that the system
configuration has the minimum
hardware requirements to
start.
2. Recover the server firmware
from the backup page (see
"Recovering the server
firmware" on page 307).
3. Update the server firmware to
the latest level.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
1. Make sure that the system
configuration has the minimum
hardware requirements to
start.
2. Update the server firmware on
the primary page.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
3. (Trained service technician
only) Replace the system
board.