Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 192

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

CAUTION:
The following label indicates sharp edges, corners, or joints nearby.
Statement 17
CAUTION:
The following label indicates moving parts nearby.
To remove a power supply, complete the following steps.
1. Read the safety information (see Chapter 2 "Safety information" on page 3).
2. Turn off the server and all attached devices; then, disconnect all power cords and external cables.
3. Unlock and remove the side cover (see "Removing the side cover" on page 146).
Note: It might be helpful to lay the server on its side for the remainder of this procedure.
4. Rotate the power-supply cage assembly out of the chassis. Lift up the power-supply cage handle and
pull the power-supply cage assembly all the way up until the retainer latch locks the cage in place
on the chassis.
1
Power supply
2
Power-supply handle
184
ThinkServer TD200 Hardware Maintenance Manual

Advertisement

Table of Contents
loading

Table of Contents