Lenovo TD200 - ThinkServer - 3809 Hardware Maintenance Manual page 248

Hardware maintenance manual
Hide thumbs Also See for TD200 - ThinkServer - 3809:
Table of Contents

Advertisement

1
ServeRAID-MR10is connector
2
PCI slot 1
Step 11. Press the ServeRAID-MR10is adapter firmly into the connector on the system board.
Step 12. Rotate the power-supply cage assembly out of the chassis. Lift up the power-supply cage handle
and pull the power-supply cage assembly all the way up until the retainer latch locks the cage in
place on the chassis.
1
Power supply
2
Power-supply handle
Step 13. Remove the air baffle (see "Removing the air baffle" on page 147).
Step 14. Remove the front fan cage assembly (see "Removing the fan cage assembly" on page 149).
Step 15. Connect one end of the black configuration signal cable to the backplane and connect the other
end to the hard disk drive backplane configuration signal cable connector on the system board.
Step 16. Complete the cabling of the ServeRAID-MR10is SAS/SATA adapter.
• For the eight drive-bay, 2.5 inch server model, connect one end of the signal cable to the drive
backplane for drive bays 0 through 3 and route the other end through the plastic slot on the
bottom of the chassis underneath the front fan cage; then, connect it to connector J8 on the
ServeRAID-MR10is SAS/SATA controller as shown in the following illustrations:
240
ThinkServer TD200 Hardware Maintenance Manual